[{"@context":"https:\/\/schema.org\/","@type":"Article","@id":"https:\/\/www.megas-p.cz\/co-potrebuje-elektroinstalace-v-male-kancelari-aby-se-v-ni-dalo-pohodlne-pracovat\/#Article","mainEntityOfPage":"https:\/\/www.megas-p.cz\/co-potrebuje-elektroinstalace-v-male-kancelari-aby-se-v-ni-dalo-pohodlne-pracovat\/","headline":"Co pot\u0159ebuje elektroinstalace v mal\u00e9 kancel\u00e1\u0159i, aby se v n\u00ed dalo pohodln\u011b pracovat?","name":"Co pot\u0159ebuje elektroinstalace v mal\u00e9 kancel\u00e1\u0159i, aby se v n\u00ed dalo pohodln\u011b pracovat?","description":"Pracovn\u00ed st\u016fl v kancel\u00e1\u0159i m\u00e1 m\u00edt podle normy \u010cSN EN 12464-1 osv\u011btlenost alespo\u0148 500 lux\u016f a na jedno pracovn\u00ed m\u00edsto se b\u011b\u017en\u011b po\u010d\u00edt\u00e1 se 4&hellip;","datePublished":"2026-11-25","dateModified":"2026-11-25","author":{"@type":"Person","@id":"https:\/\/www.megas-p.cz\/author\/#Person","name":"","url":"https:\/\/www.megas-p.cz\/author\/","identifier":1,"image":{"@type":"ImageObject","@id":"https:\/\/secure.gravatar.com\/avatar\/56990d361a15c60249588fcd5c65556d1c39f993ac5e20b5abce42fd817b46e8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/56990d361a15c60249588fcd5c65556d1c39f993ac5e20b5abce42fd817b46e8?s=96&d=mm&r=g","height":96,"width":96}},"publisher":{"@type":"Organization","name":"megas-p.cz","logo":{"@type":"ImageObject","@id":"\/logo.png","url":"\/logo.png","width":600,"height":60}},"image":{"@type":"ImageObject","@id":"https:\/\/www.megas-p.cz\/wp-content\/uploads\/Mala_kancelar_s_LED_panely_a_parapetnim_kanalem_se_zasuvkami_06eiPr.jpg","url":"https:\/\/www.megas-p.cz\/wp-content\/uploads\/Mala_kancelar_s_LED_panely_a_parapetnim_kanalem_se_zasuvkami_06eiPr.jpg","height":0,"width":0},"url":"https:\/\/www.megas-p.cz\/co-potrebuje-elektroinstalace-v-male-kancelari-aby-se-v-ni-dalo-pohodlne-pracovat\/","about":["Produkty"],"wordCount":881,"articleBody":"        Pracovn\u00ed st\u016fl v kancel\u00e1\u0159i m\u00e1 m\u00edt podle normy \u010cSN EN 12464-1 osv\u011btlenost alespo\u0148 500 lux\u016f a na jedno pracovn\u00ed m\u00edsto se b\u011b\u017en\u011b po\u010d\u00edt\u00e1 se 4 a\u017e 6 z\u00e1suvkami 230 V a se dv\u011bma datov\u00fdmi z\u00e1suvkami RJ45. K tomu pat\u0159\u00ed samostatn\u00e9 okruhy pro kuchy\u0148ku a tisk\u00e1rny a jeden uzamykateln\u00fd prostor pro switch a router. Kdy\u017e se tyhle z\u00e1klady domysl\u00ed p\u0159ed malov\u00e1n\u00edm, kancel\u00e1\u0159 funguje roky bez prodlu\u017eova\u010dek pod stoly. Jak m\u00e1 b\u00fdt nasv\u00edcen\u00e1 kancel\u00e1\u0159, kde se pracuje cel\u00fd den? Dobr\u00e9 sv\u011btlo v kancel\u00e1\u0159i nen\u00ed jen o mno\u017estv\u00ed lux\u016f. Sv\u00edtidla by nem\u011bla osl\u0148ovat ani se odr\u00e1\u017eet v monitorech, proto se do kancel\u00e1\u0159\u00ed vol\u00ed LED panely nebo line\u00e1rn\u00ed sv\u00edtidla s mikroprizmatick\u00fdm difuzorem a n\u00edzk\u00fdm indexem osln\u011bn\u00ed UGR pod 19. Barva sv\u011btla kolem 4 000 K p\u016fsob\u00ed neutr\u00e1ln\u011b a pom\u00e1h\u00e1 udr\u017eet pozornost, tepl\u00e1 3 000 K se hod\u00ed sp\u00ed\u0161 do zaseda\u010dky nebo odpo\u010dinkov\u00e9ho koutu. Stoly umis\u0165ujte tak, aby okno bylo po stran\u011b, ne za monitorem ani za z\u00e1dy. Sv\u00edtidla pak vedou soub\u011b\u017en\u011b s okny ve dvou \u0159ad\u00e1ch a \u0159ada u okna se d\u00e1 sp\u00ednat zvl\u00e1\u0161\u0165. V jasn\u00fd den se tak zbyte\u010dn\u011b nesv\u00edt\u00ed a v zim\u011b odpoledne si ka\u017ed\u00fd rozsv\u00edt\u00ed jen tam, kde sed\u00ed. Ve skladu nebo na chodb\u011b u\u0161et\u0159\u00ed \u010didlo pohybu, kter\u00e9 zhasne, kdy\u017e nikdo neproch\u00e1z\u00ed. Kolik z\u00e1suvek a datov\u00fdch p\u0159\u00edpojek pot\u0159ebuje jedno pracovn\u00ed m\u00edsto? Modern\u00ed pracovn\u00ed m\u00edsto je pln\u00e9 spot\u0159ebi\u010d\u016f, i kdy\u017e to tak na prvn\u00ed pohled nevypad\u00e1. Po\u010d\u00edta\u010d nebo dokovac\u00ed stanice, dva monitory, lampa, nab\u00edje\u010dka telefonu a ob\u010das oh\u0159\u00edvac\u00ed podlo\u017eka nebo ventil\u00e1tor. Do toho datov\u00e1 s\u00ed\u0165, kter\u00e1 by u stolu m\u011bla b\u00fdt kabelem, ne jen p\u0159es Wi-Fi. 4 a\u017e 6 z\u00e1suvek 230 V u ka\u017ed\u00e9ho stolu, ide\u00e1ln\u011b v parapetn\u00edm kan\u00e1lu nebo podlahov\u00e9 krabici. 2 datov\u00e9 z\u00e1suvky RJ45 na m\u00edsto, kabel\u00e1\u017e kategorie 6 nebo 6A veden\u00e1 do jednoho rozvad\u011b\u010de. Z\u00e1suvka s USB nab\u00edjen\u00edm u jednac\u00edho stolu a v zaseda\u010dce. Samostatn\u00fd okruh pro kuchy\u0148ku s varnou konvic\u00ed a mikrovlnkou. Okruh pro tisk\u00e1rny a server odd\u011blen\u00fd od pracovn\u00edch m\u00edst. Rezervn\u00ed z\u00e1suvky a chr\u00e1ni\u010dky pro budouc\u00ed roz\u0161\u00ed\u0159en\u00ed. Strukturovan\u00e1 kabel\u00e1\u017e se vede hv\u011bzdicov\u011b, ka\u017ed\u00e1 datov\u00e1 z\u00e1suvka m\u00e1 vlastn\u00ed kabel do patch panelu v rozvad\u011b\u010di. Kabely by nem\u011bly b\u00fdt del\u0161\u00ed ne\u017e 90 metr\u016f a nem\u011bly by b\u011b\u017eet soub\u011b\u017en\u011b t\u011bsn\u011b vedle silov\u00fdch kabel\u016f. P\u0159ehled parapetn\u00edch kan\u00e1l\u016f, datov\u00fdch z\u00e1suvek, patch panel\u016f i kancel\u00e1\u0159sk\u00fdch sv\u00edtidel si m\u016f\u017eete proj\u00edt t\u0159eba na https:\/\/onninen.pl\/cs, kde se daj\u00ed porovnat kategorie kabel\u016f i kryt\u00ed. Samotnou instalaci a m\u011b\u0159en\u00ed kabel\u00e1\u017ee ale nechte firm\u011b, kter\u00e1 vystav\u00ed protokol.  Pro\u010d na rozvad\u011b\u010di a revizi v kancel\u00e1\u0159i z\u00e1le\u017e\u00ed Rozvad\u011b\u010d v mal\u00e9 firm\u011b by m\u011bl m\u00edt jisti\u010de p\u0159ehledn\u011b popsan\u00e9 podle m\u00edstnost\u00ed a z\u00e1suvkov\u00e9 okruhy chr\u00e1n\u011bn\u00e9 proudov\u00fdm chr\u00e1ni\u010dem. Svodi\u010d p\u0159ep\u011bt\u00ed ochr\u00e1n\u00ed po\u010d\u00edta\u010de a server p\u0159i bou\u0159ce. Firma jako zam\u011bstnavatel mus\u00ed m\u00edt elektroinstalaci v po\u0159\u00e1dku a pravideln\u011b revidovanou, nejde jen o pohodl\u00ed, ale i o odpov\u011bdnost za bezpe\u010dnost lid\u00ed. Kontroluj\u00ed se i spot\u0159ebi\u010de, t\u0159eba rychlovarn\u00e1 konvice v kuchy\u0148ce nebo prodlu\u017eovac\u00ed p\u0159\u00edvody. P\u0159i st\u011bhov\u00e1n\u00ed do pronajat\u00fdch prostor se proto vyplat\u00ed vy\u017e\u00e1dat si od majitele posledn\u00ed revizn\u00ed zpr\u00e1vu. Z n\u00ed pozn\u00e1te, jak star\u00e1 je instalace a jestli v n\u00ed nejsou zapsan\u00e9 z\u00e1vady. Domluvte se tak\u00e9 p\u0159edem, kdo zaplat\u00ed p\u0159\u00edpadn\u00e9 \u00fapravy, ne\u017e za\u010dnete vrtat do zd\u00ed. Ot\u00e1zky a odpov\u011bdi Sta\u010d\u00ed v mal\u00e9 kancel\u00e1\u0159i jen Wi-Fi? Pro notebooky na sch\u016fzky ano, pro st\u00e1l\u00e1 pracovn\u00ed m\u00edsta ne. Kabel d\u00e1v\u00e1 stabiln\u00ed rychlost a n\u00edzkou odezvu p\u0159i videohovorech a nezat\u011b\u017euje bezdr\u00e1tovou s\u00ed\u0165. Datovou z\u00e1suvku u ka\u017ed\u00e9ho stolu je proto dobr\u00e9 m\u00edt, i kdy\u017e ji zat\u00edm nevyu\u017eijete. Mohu v pronajat\u00e9 kancel\u00e1\u0159i vym\u011bnit sv\u00edtidla s\u00e1m? V\u00fdm\u011bna sv\u00edtidla na st\u00e1vaj\u00edc\u00edm v\u00fdvodu je pr\u00e1ce pro elektrik\u00e1\u0159e a v pronajat\u00fdch prostorech nav\u00edc pot\u0159ebujete souhlas majitele. Sami m\u016f\u017eete bez obav doplnit stoln\u00ed lampy nebo z\u00e1suvkov\u00e9 li\u0161ty s p\u0159ep\u011b\u0165ovou ochranou. Kam um\u00edstit router a switch? Ide\u00e1ln\u011b do mal\u00e9ho uzav\u00edrateln\u00e9ho datov\u00e9ho rozvad\u011b\u010de na st\u011bnu, kam vedou v\u0161echny kabely. Router by nem\u011bl st\u00e1t na zemi pod stolem ani v uzav\u0159en\u00e9 sk\u0159\u00edni bez v\u011btr\u00e1n\u00ed, proto\u017ee se p\u0159eh\u0159\u00edv\u00e1 a zhor\u0161uje se sign\u00e1l Wi-Fi. Jak pozn\u00e1m, \u017ee je z\u00e1suvek m\u00e1lo? Typick\u00fdm znakem jsou rozdvojky zapojen\u00e9 za sebou a prodlu\u017eova\u010dky vedouc\u00ed p\u0159es pr\u016fchod. Takov\u00e9 zapojen\u00ed p\u0159et\u011b\u017euje jednu z\u00e1suvku a je to \u010dast\u00e1 p\u0159\u00ed\u010dina vypad\u00e1v\u00e1n\u00ed jisti\u010de. Je \u010das p\u0159idat okruh nebo parapetn\u00ed kan\u00e1l.                                                                                                                                                                                                                                                                                                                                                                                                  "},{"@context":"https:\/\/schema.org\/","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Co pot\u0159ebuje elektroinstalace v mal\u00e9 kancel\u00e1\u0159i, aby se v n\u00ed dalo pohodln\u011b pracovat?","item":"https:\/\/www.megas-p.cz\/co-potrebuje-elektroinstalace-v-male-kancelari-aby-se-v-ni-dalo-pohodlne-pracovat\/#breadcrumbitem"}]}]